Skip to content

Drinking water / Texas

City of Primera

PWSID TX0310094 - Harlingen

PFAS was detected in this system, below the final federal limits.

The highest result was PFBA at 13.6 ng/L. Detection below a limit is not a violation and requires no action from the utility.

5,811

people served

1,650

service connections

purchased surface water

primary source

240

sample results

Every compound detected

Highest single result per compound, in nanograms per litre (the same unit as parts per trillion). EPA proposed in May 2026 to rescind the limits marked as withdrawn, so those results are reported without a comparison.

CompoundHighest resultFederal limitReading
PFBA13.6 ng/Lnonebelow limit
PFBS10.4 ng/Lnonebelow limit
PFHxA8.8 ng/Lnonebelow limit
PFPeA8.5 ng/Lnonebelow limit
PFHxS3.4 ng/Lwithdrawnno current limit

Counties served

What this does not tell you

These are entry-point results for the system, not one tap. Water mixes between sources, sits in mains and passes through household plumbing. A certified lab test of your own tap is the only thing that answers what you drink, and it is the only route at all for a private well.

How to test your tap water

If you want to treat it

Reverse osmosis and properly specified activated carbon remove most PFAS at the tap. Certification to NSF/ANSI 53 or 58 with an explicit PFOA and PFOS claim is what separates a PFAS filter from a taste filter.

Which filters actually work

Source: EPA Fifth Unregulated Contaminant Monitoring Rule occurrence data, with system detail from EPA SDWIS. Umwelt reports these results as published. Methodology and sources